The following deating curves must be observed before installation.
DERATING CURVES
(B, C)
Load Current (Amps)
30
25
20
15
10
5
0
20 40 60
80
Ambient Temperature (ºC)
CTRx60xx
Wire Size
Maximum wire size of AWG #16 (1.3 mm
2
) on
input and AWG #8 (8.4 mm
2
) output terminals.
Connections
Ensure that wires ends are stripped to a
minimum length of 0.4 in (10 mm).
Recommended Screw Torque Range
4.4 in-lbs (0.5 Nm) on input and 12 in-lbs (1.3 Nm)
on output.